3 n o 1 n c 1 semiconductor.
Pilz relay pnoz x3.
Kg felix wankel straße 2 73760 ostfildern germany telephone.
The pnoz x3 range of safety relays by pilz introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off.
E stop pushbutton not operated.
When supply voltage is supplied the power led is lit.
49 711 3409 0 telefax.
Particularly useful in automated environments with high foot traffic such as factories and.
Automatic monitored start ub 24 v ac 24 v dc width.
E stop relays safety gate monitors pilz gmbh co.
70228528 description relay safety e stop 3 no 1 nc 24vac dc supply 24vdc 35ma input reset ctrl loop.
The sizes vary from 22 5 to 90 mm the number of contacts from two to eight.
The unit is ready for operation when the start circuit s13 s14 is closed input circuit is closed e g.
The unit is ready for operation when the start circuit s13 s14 is closed input circuit is closed e g.
Pnoz x3 2 230vac 24vdc 3n o 1n c 1so safety relay standalone inputs.
The technical features are based on voltage free electromechanical contacts with 2 relay technology.
Pnoz x3 operating manual pnoz x3 20547 en 08 8 function description the safety relay pnoz x3 provides a safety oriented interruption of a safety circuit.
The safety relays pnoz monitor safety functions such as e stop safety gates light barriers light grids two hand controls pressure sensitive mats speed standstill and much more too every day pnoz safety relays prove themselves in millions of applications worldwide.
The pnoz x3 range of safety relays by pilz introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off.
Pilz pnoz x3 ac dc relay.
Pnoz x3 24vac 24vdc 3n o 1n c 1so allied stock.
When supply voltage is supplied the power led is lit.
49 711 3409 133 e mail.
The pnoz x3 range of safety relays by pilz introduces your circuit to a safety related interruption wherein a monitored manual reset is available in this unit emergency stop relays safety gate monitors category 4 en pnoz x2 pnoz x pnoz x emergency stop relay and safety gate monitor in accordance with vde part 1 11 98 and en 12 features.
E stop pushbutton not operated.
1 2 channel wiring with detection of shorts across contacts outputs.
Our pnoz x safety relays are proven through their reliability and sturdiness.
Pnoz x3 operating manual pnoz x3 20547 en 10 9 function description the safety relay pnoz x3 provides a safety oriented interruption of a safety circuit.
They are used in a wide range of applications and in the most diverse safety applications.
Use one pnoz x per safety function.
45 mm integral screw terminals monitoring e stop safety gates supply interruption before de energisation approx.